Draft
Approve this draft to open the ECR.
Initial Inspection
Deadline TBD
Assessment
Deadline TBD
Final Inspection
Deadline TBD
Closed
Deadline TBD
QCR-100453

Created from BLD-10233 - PO #4938 - Bluepoint EMS

Item Details

Manufacturer part number
XC3S400-4PQ208C
Part manufacturer
Xilinx
Part number
000002
Type
[IC]
Description
Spartan-3 FPGA Lorem ipsum dolor sit amet, consectetuer adipiscing elit.
Comment
400,000-gate
Material Location Chicago (CH)
Build BLD-10233 - PO #4938 - Swabian
Source BLD-10233 PO #4938 QCR-2
Purchase Order PO #2122
Initial Condition
Cosmetic
Non conforming
Minor
Functional
Non conforming
N/A
Safety
Non conforming
Critical
Compliance
Non conforming
Major
Final Condition
Cosmetic
Conforming
N/A
Functional
Non conforming
Critical
Safety
Non conforming
Major
Compliance
Unknown
N/A
Root Cause(s)
Design
Power Supply Power Supply Power Supply Power Supply +8
Handling
Power Supply Power Supply Power Supply Power Supply +8
Power Supply Power Supply Power Supply Power Supply Power Supply Power Supply Power Supply Power Supply Power Supply Power Supply
Transportation
Power Supply Power Supply Power Supply Power Supply +8
Disposition Accept
Disposition Electronic Rework
Disposition Bad Bin
Disposition To Be Determined

QCR Journal View

  • Statler H.•• QCR-012 06:28 •• 2020-03-14
    This is a highlighted comment.
    The new part number (1022393) is on order and is expected to arrive before the PCBs return from fabrication.
  • QCR-012 created- Active : User-Defined Stage 18:03 •• 2024-11-29
    Statler H. created the Quality Control Record. Quantity 50
  • Statler H.•• QCR-011 06:28 •• 2020-03-14
    This is an unread comment.
    The new part number (1022393) is on order and is expected to arrive before the PCBs return from fabrication.
  • QCR-011 Closed 18:03 •• 2024-11-29
    Nebojša Stričević, Jr. closed the Quality Control Record.
  • Statler H.•• QCR-011 06:28 •• 2020-03-14
    All schematics have been updated and checked in.
    The new part number (1022393) is on order and is expected to arrive before the PCBs return from fabrication.
  • QCR-011 moved 16:03 •• 2024-11-29
    Nebojša Stričević, Jr. moved the Quality Control Record.
  • Statler H.•• QCR-011 06:28 •• 2020-03-14
    All schematics have been updated and checked in.
    The new part number (1022393) is on order and is expected to arrive before the PCBs return from fabrication.
  • QCR-011 created- Closed 16:03 •• 2024-11-29
    Rework - Bin name here? - Disposition note here?
    Initial Condition
    Cosmetic
    Non conforming
    Minor
    Functional
    Non conforming
    N/A
    Safety
    Non conforming
    Critical
    Compliance
    Non conforming
    Major
    Final Condition
    Cosmetic
    Conforming
    N/A
    Functional
    Non conforming
    Critical
    Safety
    Non conforming
    Major
    Compliance
    Unknown
    N/A
    Root Cause(s) Proccess, Manufacturing, Component
    Disposition To be determined
  • QCR split 16:03 •• 2024-11-29
    Quantinty 100 out of 150 Split from QCR-010
  • QCR-010 created- Active : User-Defined Stage 16:03 •• 2024-11-29
    Statler H. created the Quality Control Record. Quantity 150
    Initial Condition
    Cosmetic
    Non conforming
    Minor
    Functional
    Non conforming
    N/A
    Safety
    Non conforming
    Critical
    Compliance
    Non conforming
    Major
    Final Condition
    Cosmetic
    Conforming
    N/A
    Functional
    Non conforming
    Critical
    Safety
    Non conforming
    Major
    Compliance
    Unknown
    N/A
    Root Cause(s) Proccess, Manufacturing, Component
    Disposition To be determined
  • Henry F. 06:28 •• 2020-03-14
    During our meeting, we selected 1022393 as the zener for the snubber diode.
Affected Parts